1.
World Neurosurg ; 156: e300-e306, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34560299

RESUMO

OBJECTIVE: To evaluate the feasibility of O-arm navigation of bilateral dual sacral-alar-iliac (SAI) screws compared with conventional bilateral single SAI and S1 pedicle screws for pelvic anchors in cases of adult spinal deformity. METHODS: This retrospective, comparative study included 39 patients who underwent corrective fusion using SAI screws from T10 to the pelvis. Patients were divided into 2 groups according to the number of SAI screws placed during adult spinal deformity surgery: single SAI screw (group S, 17 cases) and dual SAI screws (group D, 22 cases). The incidence of rod breakage, proximal junctional kyphosis, screw loosening, reoperation, and global alignment in each group was estimated. Postoperative patient-reported outcomes were measured using the Oswestry Disability Index, Japanese Orthopaedic Association Back Pain Evaluation Questionnaire, and visual analog scale. RESULTS: The incidence of SAI screw loosening was significantly lower in group D than in group S (23% vs. 65%, P = 0.011). The rod breakage incidence was 0% and 12% in groups D and S, respectively (P = 0.17). There were no significant differences in the postoperative global alignment and clinical outcomes between the 2 groups. CONCLUSIONS: Dual SAI screws were associated with a significantly reduced incidence of screw loosening compared with single SAI screws. The bilateral dual SAI screws technique for pelvic anchors is feasible for the treatment of patients with adult spinal deformity.


Assuntos
Ílio/cirurgia , Procedimentos Neurocirúrgicos/métodos , Parafusos Pediculares , Região Sacrococcígea/cirurgia , Coluna Vertebral/anormalidades , Coluna Vertebral/cirurgia , Idoso , Dor nas Costas/diagnóstico , Avaliação da Deficiência , Falha de Equipamento/estatística & dados numéricos , Feminino , Humanos , Incidência , Cifose/epidemiologia , Masculino , Pessoa de Meia-Idade , Medição da Dor , Complicações Pós-Operatórias/epidemiologia , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fusão Vertebral/métodos , Resultado do Tratamento
2.
Adv Skin Wound Care ; 34(9): 1-6, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34415257

RESUMO

OBJECTIVE: To investigate the protective effect of a hydrocolloid nasal dressing on the incidence and severity of nasal injury and continuous positive airway pressure (CPAP) failure in preterm infants receiving nasal CPAP (N-CPAP). METHODS: A randomized controlled trial was conducted over 4 months in 2019 at level 3 neonatal ICUs in two hospitals affiliated with Isfahan University of Medical Sciences, Iran. Eighty eligible infants were born at 32 weeks of gestation or younger and/or with a birth weight of 1,500 g or less and had received between 4 and 72 hours of CPAP. Infants were randomly assigned to two groups; the intervention group used a protective dressing, and the control group received routine care. Data collection tools included a demographic questionnaire and nasal injury assessment score chart. MAIN OUTCOME MEASURES: The incidence and severity of nasal injury in preterm infants undergoing N-CPAP. RESULTS: Infants in the intervention group had a significantly lower incidence and severity of nasal injury compared with the control group: 15 of 40 (37.5%) versus 37 of 40 (92.5%; P < .001). Overall, the injuries identified in this study were mostly mild and moderate, with only three severe injuries in the intervention group and five in the control group. No significant differences were detected in CPAP failure (P > .05). CONCLUSIONS: The studied nasal barrier dressing is a safe and convenient solution to reduce nasal injury in preterm infants receiving N-CPAP.


Assuntos
Bandagens/normas , Pressão Positiva Contínua nas Vias Aéreas/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Ferimentos e Lesões/etiologia , Bandagens/estatística & dados numéricos , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Feminino , Humanos , Incidência , Recém-Nascido , Recém-Nascido Prematuro/fisiologia , Unidades de Terapia Intensiva Neonatal/organização & administração , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Irã (Geográfico)/epidemiologia , Masculino , Síndrome do Desconforto Respiratório/epidemiologia , Síndrome do Desconforto Respiratório/terapia , Ferimentos e Lesões/epidemiologia
3.
Emerg Med J ; 38(10): 776-779, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34429370

RESUMO

BACKGROUND: We aimed to determine the incidence, nature of and predisposing factors for risk events (REs) that occur during the intrahospital transport of patients from the ED. METHODS: We undertook a prospective, observational study of intrahospital patient transports from a single ED between 30 January and 20 March 2020. An investigator attended each transport and recorded any RE on a specifically designed data collection document. An RE was any mishap, even if not foreseen, that had the potential to cause the patient harm. A patient equipment number was assigned based on the number of pieces of equipment required during the transport. Poisson regression generated incidence rate ratios (IRRs) and determined risk factors for REs. RESULTS: Of 738 transports, 289 (39.1%, 95% CI 35.6% to 42.8%) had at least one RE. The total of 521 REs comprised 125 patient-related, 279 device-related and 117 line/catheter-related REs. The most common included trolley collisions (n=142), intravenous fluid line catching/tangling (n=93), agitation/aggression events (n=31) and cardiac monitoring issues (n=31). Thirty-four (6.5%) REs resulted in an undesirable patient outcome, most commonly distress and pain. Predisposing factors for REs included an equipment number ≥3 (IRR 5.68, 95% CI 3.95 to 8.17), transport to a general ward (IRR 2.68, 95% CI 2.12 to 3.39), hypertension (IRR 1.93, 95% CI 1.07 to 3.50), an abnormal temperature and a GCS<14. CONCLUSIONS: REs are common in transport of patients from the ED and can result in undesirable patient outcomes. Adequate pre-transfer preparation, especially securing equipment and lines, would result in a reduced risk.


Assuntos
Serviço Hospitalar de Emergência/normas , Transferência de Pacientes/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Estado Terminal/terapia , Serviço Hospitalar de Emergência/organização & administração , Serviço Hospitalar de Emergência/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Transferência de Pacientes/classificação , Transferência de Pacientes/estatística & dados numéricos , Estudos Prospectivos , Agitação Psicomotora/tratamento farmacológico , Agitação Psicomotora/prevenção & controle , Fatores de Risco , Vitória
4.
Heart Rhythm ; 18(12): 2072-2079, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34214647

RESUMO

BACKGROUND: To date, only a few comparisons between subcutaneous implantable cardioverter-defibrillator (S-ICD) patients undergoing and those not undergoing defibrillation testing (DT) at implantation (DT+ vs DT-) have been reported. OBJECTIVE: The purpose of this study was to compare long-term clinical outcomes of 2 propensity-matched cohorts of DT+ and DT- patients. METHODS: Among consecutive S-ICD patients implanted across 17 centers from January 2015 to October 2020, DT- patients were 1:1 propensity-matched for baseline characteristics with DT+ patients. The primary outcome was a composite of ineffective shocks and cardiovascular mortality. Appropriate and inappropriate shock rates were deemed secondary outcomes. RESULTS: Among 1290 patients, a total of 566 propensity-matched patients (283 DT+; 283 DT-) served as study population. Over median follow-up of 25.3 months, no significant differences in primary outcome event rates were found (10 DT+ vs 14 DT-; P = .404) as well as for ineffective shocks (5 DT- vs 3 DT+; P = .725). At multivariable Cox regression analysis, DT performance was associated with a reduction of neither the primary combined outcome nor ineffective shocks at follow-up. A high PRAETORIAN score was positively associated with both the primary outcome (hazard ratio 3.976; confidence interval 1.339-11.802; P = .013) and ineffective shocks alone at follow-up (hazard ratio 19.030; confidence interval 4.752-76.203; P = .003). CONCLUSION: In 2 cohorts of strictly propensity-matched patients, DT performance was not associated with significant differences in cardiovascular mortality and ineffective shocks. The PRAETORIAN score is capable of correctly identifying a large percentage of patients at risk for ineffective shock conversion in both cohorts.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/estatística & dados numéricos , Análise de Falha de Equipamento , Falha de Equipamento/estatística & dados numéricos , Taquicardia Ventricular , Pesquisa Comparativa da Efetividade , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/estatística & dados numéricos , Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/estatística & dados numéricos , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Teste de Materiais/métodos , Teste de Materiais/estatística & dados numéricos , Pessoa de Meia-Idade , Pontuação de Propensão , Medição de Risco/métodos , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/terapia
5.
JAMA Intern Med ; 181(9): 1217-1223, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34309624

RESUMO

Importance: In the US, most postmarket medical device safety data are obtained through adverse event reports that are submitted to the US Food and Drug Administration (FDA)'s Manufacturer and User Facility Device Experience (MAUDE) database. Adverse event reports are classified by the reporter as injury, malfunction, death, or other. If the device may have caused or contributed to a death, or if the cause of death is unknown, the FDA requires that the adverse event be reported as a death. Objective: To determine the percentage of medical device adverse event reports submitted to the MAUDE database that were not classified as death even though the patient died. Design, Setting, and Participants: In this study, a natural language processing algorithm was applied to the MAUDE database, followed by manual text review, to identify reports in the injury, malfunction, other or missing categories that included at least 1 term that suggested a patient death, such as patient died or patient expired, from December 31, 1991, to April 30, 2020, for any medical device. Exposures: Manual review of a random sample of 1000 adverse event reports not classified as death and of selected reports for 62 terms that are associated with deaths but were not classified as death. Main Outcomes and Measures: Percentage of adverse event reports in which the patient was said to have died in the narrative section of the report but the reporter classified the report in a category other than death. Results: The terms in the natural language processing algorithm identified 290 141 reports in which a serious injury or death was reported. Of these, 151 145 (52.1%) were classified by the reporter as death and 47.9% were classified as malfunction, injury, other, or missing. For the overall sample, the percentage of reports with deaths that were not classified as deaths was 23% (95% CI, 20%-25%), suggesting that approximately 31 552 reports in our sample had deaths that were classified in other categories. The overall percentage of missed deaths, defined as the percentage of deaths that were classified in other categories, was 17% (95% CI, 16%-19%). Conclusions and Relevance: Many of the findings of this study suggest that many medical device adverse event reports in the FDA's MAUDE database that involved a patient death are classified in categories other than death. As the FDA only routinely reviews all adverse events that are reported as patient deaths, improving the accuracy of adverse event reporting may enhance patient safety.


Assuntos
Falha de Equipamento/estatística & dados numéricos , Segurança de Equipamentos/estatística & dados numéricos , Equipamentos e Provisões/efeitos adversos , Vigilância de Produtos Comercializados/estatística & dados numéricos , United States Food and Drug Administration/estatística & dados numéricos , Causas de Morte , Bases de Dados Factuais , Seguimentos , Humanos , Segurança do Paciente , Estudos Retrospectivos , Estados Unidos/epidemiologia
6.
Br J Radiol ; 94(1125): 20210475, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34289324

RESUMO

OBJECTIVES: To determine biopsy device failures, causative factors, complications and sample quality of the 16G end-cut Biopince™ and side-notch Bard™ needles. METHODS: All ultrasound-guided non-targeted liver biopsies between 01/01/2016 and 31/12/2018 were included. Operator, device, number of failures, complications and repeat biopsies were recorded. Histopathology samples were reviewed for all cases of needle failure and a group with no failures, and graded "yes/no" for the presence of steatosis, inflammation and fibrosis. The pathology slides from these cases were reviewed to assess biopsy sample quality (length and portal tract number). The failure and no-failure groups were compared in terms of device type/histology, and sample quality was compared between the needle types. RESULTS: 1004 patients were included. 93.8% (n = 942) required one needle pass to obtain a sample and 6.2% (n = 62) required >1 pass due to needle failure. Total of 76 needle failures, more with end-cut than side-notch needles (8.7% vs 2.9%) (p < 0.001). No needle failures resulted in complication. The presence of liver fibrosis was associated with fewer needle failures (p = 0.036). The major complication rate was 0.4% (4/1044). A biopsy with >10 portal tracts was obtained in 90.2% of specimens > 20 mm long, compared with 66% of 16-20 mm biopsies and 21% of <16 mm biopsies. The target of >10 portal tracts was achieved in 10/26 (38.5%) of side-notch biopsies and 64/90 (71.1%) of end-cut biopsies (p = 0.004). CONCLUSION: Ultrasound-guided liver biopsy is safe and sample quality is consistently good when a core >20 mm long is obtained. The end-cut biopsy device generated reliably good quality biopsy samples; however, the needle failure rate was significantly higher than the side-cut needle. ADVANCES IN KNOWLEDGE: Ultrasound-guided liver biopsy specimen quality is consistently good when a core >20 mm long is obtained which can be achieved with a single pass using the 16G BiopinceTM end-cut needle, although the needle failure rate is significantly higher than the 16G Max-Core™ Bard™ side-notch needle.


Assuntos
Falha de Equipamento/estatística & dados numéricos , Fígado/patologia , Ultrassonografia de Intervenção/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Desenho de Equipamento , Feminino , Humanos , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
7.
West J Emerg Med ; 22(3): 547-551, 2021 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-34125025

RESUMO

INTRODUCTION: The coronavirus 2019 pandemic caused a shortage of disposable N95 respirators, prompting healthcare entities to extend the use of these masks beyond their intended single-use manufacturer recommendation with a paucity of supporting research. METHODS: We performed a prospective cohort study of ED healthcare workers (HCW) ("subjects") required to use respirators at an academic, Level I trauma center. Subjects had been previously fit tested and assigned an appropriately sized N95 mask per hospital protocol. Per study protocol, subjects were fit tested periodically throughout their shifts and on multiple shifts over the eight-week study period. Data points collected included the age of the mask, subjective assessment of mask seal quality, and fit test results. We analyzed the data using Fisher's exact test, and calculated odds ratios (OR) to determine the failure rate of disposable N95 masks following reuse. RESULTS: A total of 130 HCWs underwent fit testing and 127 were included for analysis. Mask failure rate climbed after day 2 of use, with 33.3% of masks failing at day 3, 42.9% at day 4, and 50% at ≥ day 5. Categorizing the masks into those being used for two or fewer days vs those in use for three or more, failure was more common on day 3 of use or older compared to those in the first two days of use (41.8% vs 8.3%, P < 0.0001) with an OR of failure with an older mask of 7.9 (confidence interval [CI], 2.8-22.3). The healthcare workers' assessment of poor seal was 33.3% sensitive (CI, 18.6-51.9) and 95.7% specific (CI, 88.8-98.6) for fit test failure. CONCLUSION: Disposable N95 masks have significant failure rates following reuse in clinical practice. Healthcare personnel also performed poorly in assessing the integrity of the seal of their disposable respirators.


Assuntos
Falha de Equipamento/estatística & dados numéricos , Reutilização de Equipamento , Respiradores N95 , COVID-19/epidemiologia , COVID-19/prevenção & controle , Equipamentos Descartáveis , Serviço Hospitalar de Emergência , Humanos , Pandemias , Estudos Prospectivos
8.
Am J Cardiol ; 152: 78-87, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34116792

RESUMO

Left atrial appendage closure (LAAC) is an important strategy to reduce stroke risk in patients with non-valvular atrial fibrillation (AF) who are at high risk of bleeding on long-term anticoagulation. Real-world assessments of the safety of the Watchman LAAC device remain limited. The objective of this study was to determine the frequency and timing of adverse events associated with Watchman LAAC device implants performed after FDA approval. Adverse events associated with Watchman LAAC implants performed between March 2015 and March 2019 were identified through a search of the FDA Manufacturer and User Facility Device Experience (MAUDE) database. During the study period, 3,652 unique adverse events were identified. An estimated 43,802 Watchman implants were performed in the United States during the study period. The overall adverse event rate was 7.3% and the mortality rate was 0.4%. Of the 159 unique types of adverse events identified, pericardial effusion was most common (1.4%). Most adverse events (73%) occurred intraoperatively (59%) or within 1 day of the procedure (15%). However, 19% of deaths, 24% of strokes and 27% of device embolizations occurred >1 month after implantation. The rates of most Watchman-related adverse events reported in the MAUDE database were comparable to those observed in clinical trials. A majority of adverse events occurred within 1 day of implant. In conclusion, while the absolute event rates were low, a significant proportion of device embolizations, strokes, and deaths occurred >1 month after Watchman implant.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos , Complicações Intraoperatórias/epidemiologia , Derrame Pericárdico/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Implantação de Prótese , Acidente Vascular Cerebral/prevenção & controle , Fibrilação Atrial/complicações , Tamponamento Cardíaco/epidemiologia , Bases de Dados Factuais , Aprovação de Equipamentos , Falha de Equipamento/estatística & dados numéricos , Humanos , Hipotensão/epidemiologia , Mortalidade , Próteses e Implantes , Falha de Prótese , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Trombose/epidemiologia , Fatores de Tempo
9.
Urology ; 156: 211-215, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33971189

RESUMO

OBJECTIVE: To examine voluntary reports in the Food & Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database, categorize complications and assign device-related causality with transurethral resection of the prostate (TURP), prostatic urethral lift (PUL), and transurethral water vapor therapy (TWVT). METHODS: A review was performed using the terms "Urolift," "Rezum," and "transurethral resection of the prostate" between 01/01/2015 and 12/31/2019. Duplicate and incomplete reports were excluded. The Gupta system was used to report complications and device related causality.1 Pearson's Chi-square analysis was performed to compare minor (Level 1) versus major (Levels 2-4) complications. RESULTS: A total of 548 events were examined. After removal of duplicates (n = 60), irrelevant reports (n=65), and incomplete information (n = 14), we included 409 events (74.6%). Of the 409 events, 214 were for TURP, 112 for TWVT, and 83 for PUL. In aggregate, 39.4% of events were minor/Level 1 (n=161/409). The proportion of subjects with Level 2-4 complications versus Level 1 complications was significantly higher for PUL than TURP or TWVT [X2 (2, N = 408) = 41.4023, P < .00001]. Device causality was attributable to device malfunction in 60.4% of cases (n=247/409). CONCLUSION: Device malfunction was noted in all groups and 39.4% of these were minor (Level 1). However, the majority of PUL reports noted a Level 3 or 4 complication (50.6%, 42/83), primarily bleeding related. Previous studies have not revealed significant risk of bleeding and suggests a discrepancy between study data and real-world experience that may alter patient counseling practices.


Assuntos
Bases de Dados Factuais , Falha de Equipamento/estatística & dados numéricos , Complicações Pós-Operatórias/etiologia , Vigilância de Produtos Comercializados , Prostatectomia/efeitos adversos , Prostatectomia/instrumentação , Hiperplasia Prostática/cirurgia , United States Food and Drug Administration , Obstrução do Colo da Bexiga Urinária/cirurgia , Humanos , Masculino , Hiperplasia Prostática/complicações , Índice de Gravidade de Doença , Estados Unidos , Obstrução do Colo da Bexiga Urinária/etiologia
10.
Arch Dis Child Fetal Neonatal Ed ; 106(6): 663-667, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33963004

RESUMO

OBJECTIVE: To determine leakage for two neonatal continuous positive airway pressure (CPAP) interfaces and evaluate leak-corrective manoeuvres. DESIGN: The ToNIL (Trial of NCPAP Interface Leakage) study was a randomised, clinical, cross-over trial with data collection between August 2018 and October 2019. The primary outcome was blinded to the treating staff. SETTING: One secondary, 8-bed neonatal intensive care unit (NICU) and three larger (>15 beds), academic NICU referral centres. PATIENTS: Newborn infants with CPAP were screened (n=73), and those with stable spontaneous breathing, low oxygen requirement, postmenstrual age (PMA) over 28 weeks and no comorbidities were eligible. In total, 50 infants were included (median PMA 33 completed weeks). INTERVENTIONS: Leakage was measured for both prongs and nasal mask, before and after leak-corrective manoeuvres. Interface application was performed in a randomised order by a nurse, blinded to the measured leakage. MAIN OUTCOME MEASURES: 30 s average leakage, measured in litres per minute (LPM). RESULTS: Analyses showed a significantly lower leakage (mean difference 0.86 LPM, 95% CI 0.07 to 1.65) with prongs (median 2.01 LPM, IQR 1.00-2.80) than nasal mask (median 2.45 LPM, IQR 0.99-5.11). Leak-corrective manoeuvres reduced leakage significantly for both prongs (median 1.22 LPM, IQR 0.54-1.87) and nasal mask (median 2.35 LPM, IQR 0.76-4.75). CONCLUSIONS: Large leakages were common for both interfaces, less with prongs. Simple care manoeuvres reduced leakage for both interfaces. This is the first report of absolute leakage for nasal interfaces and should encourage further studies on leakage during CPAP treatment.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Falha de Equipamento/estatística & dados numéricos , Cuidado do Lactente , Máscaras , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Estudos Cross-Over , Feminino , Idade Gestacional , Humanos , Cuidado do Lactente/instrumentação , Cuidado do Lactente/métodos , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Masculino , Máscaras/efeitos adversos , Máscaras/classificação , Máscaras/normas , Avaliação de Processos e Resultados em Cuidados de Saúde , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia
11.
Sci Rep ; 11(1): 10212, 2021 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-33986385

RESUMO

Peritonitis is a common complication of peritoneal dialysis (PD). Our root cause analysis allowed to attribute some cases to leakage of the PD catheter. Accordingly, a clinically based stress test study on potential material damage issues of PD catheters was performed, focusing on material damage caused by cleaning, de- and attachment procedures during dialysate changes and on the individual storage methods of PD catheters between dialysate changes. PD catheters were exposed to both chemical stress by repeating dialysate-flow and physical stress simulating de- and connecting, fixation, pressure, flexing, folding etc.-simulating standard clinical daily routine of 8-10 years PD catheter usage. Potentially by normal usage caused damages should be then detected by intraluminal pressure, light- and electron microscopy. The multi-step visual control showed no obvious damages on PD catheters nor any leakage or barrier indulgence. Our tests simulating daily routine usage of PD catheters for several years could not detect any material defects under chemical or physical stress. Hence, we presume that most PD catheter damages, as identified cause for peritonitis in some of our patients, may be due to accidental, unnoticed external damage (e.g. through scissors, while changing dressings) or neglecting PD catheter handling specifications.


Assuntos
Cateteres/efeitos adversos , Testes Mecânicos/métodos , Diálise Peritoneal/efeitos adversos , Cateteres de Demora/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Humanos , Diálise Peritoneal/métodos , Diálise Peritoneal Ambulatorial Contínua/efeitos adversos , Peritonite/etiologia , Peritonite/prevenção & controle , Estresse Mecânico
12.
BMC Cancer ; 21(1): 576, 2021 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-34011301

RESUMO

BACKGROUND: Malignant gastric outlet obstruction (MGOO) occasionally occurs due to pancreaticobiliary cancer. Endoscopic duodenal stenting (DS) is a common treatment for MGOO. However, it has been reported that DS does not have sufficient patency time for it to be used in patients who have a potentially increased lifespan. Nowadays, systemic chemotherapy for pancreaticobiliary cancer has developed, and its anti-tumour effect would make time to stent dysfunction longer. Therefore, we retrospectively evaluated the association between objective response to systemic chemotherapy, followed by DS and time to stent dysfunction in patients with advanced pancreaticobiliary cancer. METHODS: This retrospective study included 109 patients with advanced pancreaticobiliary cancer who received systemic chemotherapy after DS. Patients who showed complete or partial response were defined as responders. The rest were defined as non-responders. Time to stent dysfunction was compared between responders and non-responders using the landmark analysis at 2 months after DS. Death without recurrence of MGOO was considered as a competing risk for time to stent dysfunction. RESULTS: Combination and monotherapy regimens were adopted for 46 and 63 patients, respectively. Median progression-free survival and overall survival were 3.2 months (95% confidence interval [CI], 2.4-4.0) and 6.0 months (95% CI, 4.6-7.3). Objective response was observed in 21 patients (19.3%). Median time to stent dysfunction was 12.5 months (95% CI, 8.4-16.5) in the entire cohort. In 89 patients, responders had a lower cumulative incidence of stent dysfunction than non-responders: 9.5 and 19.1% at 6 months, and 19.0 and 27.9% at 1-year, respectively. There was difference of time to stent dysfunction between responders and non-responders among patients who received combination regimen as the first-line treatment with p-value of 0.009: cumulative incidence was 0 and 42.9% at 6 months, and 9.3 and 57.1% at 1-year, respectively. CONCLUSIONS: Longer time to stent dysfunction is expected when systemic chemotherapy following DS suppresses tumour progression; DS is slated to be a standard treatment for MGOO even in patients with pancreaticobiliary cancer and a long lifespan.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Endoscopia Gastrointestinal/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Obstrução da Saída Gástrica/cirurgia , Neoplasias Gastrointestinais/tratamento farmacológico , Neoplasias Pancreáticas/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Endoscopia Gastrointestinal/instrumentação , Endoscopia Gastrointestinal/métodos , Endoscopia Gastrointestinal/estatística & dados numéricos , Feminino , Derivação Gástrica/estatística & dados numéricos , Obstrução da Saída Gástrica/etiologia , Neoplasias Gastrointestinais/complicações , Neoplasias Gastrointestinais/mortalidade , Neoplasias Gastrointestinais/patologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Neoplasias Pancreáticas/complicações , Neoplasias Pancreáticas/mortalidade , Neoplasias Pancreáticas/patologia , Intervalo Livre de Progressão , Estudos Retrospectivos , Stents/efeitos adversos , Stents/estatística & dados numéricos , Fatores de Tempo
13.
Am J Surg ; 221(6): 1121-1126, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33745689

RESUMO

BACKGROUND: We compared surgical device malfunction reports in the Food and Drug Administration (FDA) public Manufacturer and User Facility Device Experience (MAUDE) with those in the FDA nonpublic Alternative Summary Reporting (ASR). METHODS: General surgery device product code categories in MAUDE and ASR from 1999 to 2018 were identified. Changes in the rates of categories and adverse events were evaluated by Poisson regression. RESULTS: There were 283,308 (72%) general surgical device malfunctions in MAUDE and 109,954 (28%) in ASR. Reports increased annually in ASR versus MAUDE, particularly for surgical staplers and clip devices (p < 0.05). ASR contained approximately 80% of these reports; MAUDE 20%. In MAUDE, 42.9% of surgical device malfunctions and 20.2% of stapler/clip malfunctions resulted in patient injury or death. ASR listed no injury or death information. CONCLUSIONS: ASR contained a significant portion of surgical device malfunctions hidden from public scrutiny. Access to such data is essential to safe surgical care.


Assuntos
Falha de Equipamento/estatística & dados numéricos , Instrumentos Cirúrgicos/efeitos adversos , Bases de Dados Factuais , Análise de Falha de Equipamento , Humanos , Estudos Retrospectivos , Estados Unidos , United States Food and Drug Administration
14.
PLoS One ; 16(3): e0248645, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33735282

RESUMO

OBJECTIVE: Failure of membrane oxygenator (MO) function of venovenous extracorporeal membrane oxygenators (VV ECMO) remains problematic. The development of device-induced coagulation disorder (COD) or worsened gas transfer (WGT) necessitates a system exchange. The aim was to correlate von Willebrand factor antigen (vWF:Ag) with the predisposition to MO failure and mortality. METHODS: Laboratory parameters (inflammation, coagulation) and ECMO-related data from 31 VV ECMO patients were analyzed before and after the first MO exchange. Study groups were identified according to the exchange reasons (COD, WGT) and the extent of vWF:Ag (low, ≤425%; high, >425%). RESULTS: vWF:Ag remained unchanged after system exchange. High vWF:Ag was associated with systemic endothelial activation of older and obese patients with elevated SOFA score, increased norepinephrine and higher requirement of continuous renal replacement therapy without an effect on MO runtime and mortality. Including the mechanism of MO failure (COD, WGT), various patient group emerged. COD/low vWF:Ag summarized younger and less critically ill patients that benefit mainly from ECMO by a significant improvement of their inflammatory and coagulation status (CRP, D-dimers, fibrinogen) and highest survival rate (91%). Instead, WGT/high vWF:Ag presented older and more obese patients with a two-digit SOFA score, highest norepinephrine, and aggravated gas transfer. They benefited temporarily from system exchange but with worst survival (33%). CONCLUSIONS: vWF:Ag levels alone cannot predict early MO failure and outcome in VV ECMO patients. Probably, the mechanism of clotting disorder in combination with the vWF:Ag level seems to be essential for clot formation within the MO. In addition, vWF:Ag levels allows the identification different patient populations In particular, WGT/high vWF:Ag represented a critically ill population with higher ECMO-associated mortality.


Assuntos
Lesão Pulmonar Aguda/terapia , Falha de Equipamento/estatística & dados numéricos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenadores de Membrana/efeitos adversos , Trombose/epidemiologia , Lesão Pulmonar Aguda/sangue , Adulto , Idoso , Antígenos/sangue , Antígenos/imunologia , Testes de Coagulação Sanguínea/métodos , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oxigenadores de Membrana/estatística & dados numéricos , Estudos Retrospectivos , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Trombose/sangue , Trombose/diagnóstico , Trombose/etiologia , Adulto Jovem , Fator de von Willebrand/imunologia
15.
Am J Otolaryngol ; 42(4): 102968, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33676070

RESUMO

PURPOSE: Active transcutaneous Bone Conduction Implants (BCIs) are relatively new to the market and may offer improved outcomes while reducing skin-related complications associated with previous models. The purpose of this study is to examine medical device reports (MDRs) submitted to the Food and Drug Administration's (FDA) Manufacturer and User Device Facility Experience (MAUDE) database to identify adverse events with the active, transcutaneous BCIs, Bonebridge and Osia. METHODS: A search of the FDA MAUDE database was conducted using product code "PFO" (for Active Implantable Bone Conduction Hearing System), brand names "Bonebridge" and "Osia." Data was collected on device malfunction, patient injury, inciting events, and subsequent interventions between July 1, 2018 and November 1, 2020. RESULTS: The search query yielded 83 reports that met inclusion criteria, 56 regarding Bonebridge and 27 regarding Osia. A total of 91 adverse events were reported, including 45 device malfunctions and 46 patient injuries. Of all adverse events reported for Bonebridge, 15 (26.3%, 15/57) documented patient injuries, while the majority (73.7%, 42/57) documented device malfunctions. Of all adverse events reported for Osia, 3 (8.8%, 3/34) were reported concerning malfunctions, while 31 (91.2%, 31/34) were reported for patient injuries. The most commonly reported adverse events included lack of conduction or hearing (n = 26, 28.6%), infection (n = 14, 15.4%), and intermittent or reduced conduction or hearing (n = 12, 13.2%). From the MAUDE database reported adverse events and the total number of Osia implants given to us from Cochlear over this 28 month period, we estimate patient injuries to occur in roughly 2.1% of patients. CONCLUSION: There are limitations to the database which make systemic analysis challenging. This study suggests that patients with transcutaneous, active BCIs may be experiencing fewer soft tissue injuries, but similar device malfunctions as those with previous models.


Assuntos
Condução Óssea , Implante Coclear/efeitos adversos , Implantes Cocleares/efeitos adversos , Perda Auditiva Condutiva/cirurgia , Implante Coclear/métodos , Bases de Dados Factuais , Falha de Equipamento/estatística & dados numéricos , Feminino , Perda Auditiva Condutiva/fisiopatologia , Humanos , Masculino , Estados Unidos , United States Food and Drug Administration
16.
J Neurosurg Pediatr ; 27(5): 518-524, 2021 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-33636695

RESUMO

OBJECTIVE: Myelomeningocele (MMC) is frequently complicated by symptomatic hydrocephalus, necessitating early permanent CSF diversion and revision surgeries. Shunt infections are a common cause of shunt malfunction. This study aims to characterize long-term shunt-related outcomes of patients undergoing MMC closure. METHODS: A total of 170 patients undergoing MMC closure between the years of 1995 and 2017 were identified from a retrospective review of a prospectively populated surgical database at the Children's Hospital of Pittsburgh. Patients who underwent MMC closure and required ventriculoperitoneal (VP) shunt insertion met criteria and were included in the primary study analysis. Analysis with a Fisher exact test was performed for categorical variables, and Mann-Whitney U-tests were utilized for numerical data. RESULTS: Of the 158 total patients undergoing MMC closure and meeting inclusion criteria, 137 (87%) required VP shunt insertion. These 137 patients demonstrated a shunt revision rate of 21.1% per person-year and a shunt infection rate of 2.1% per person-year over a mean follow-up of 10.8 years. Patients had a mean of 3.4 ± 0.6 shunt surgeries prior to their first infection. Patients undergoing immediate shunt removal, external ventricular drain placement, or shunt replacement after clearing the infection had lower rates of subsequent infections than patients who initially were managed with shunt externalization (p < 0.001). Placement of a shunt at the time of MMC closure was not found to be a risk factor for infection. Of patients with initial shunt placement after the implementation of the Hydrocephalus Clinical Research Network protocol in 2011, the authors' institution has had a shunt infection rate of 4.2% per person-year and a revision rate of 35.7% per person-year. CONCLUSIONS: This study describes long-term outcomes of shunted MMC patients and factors associated with shunt infections. Most patients underwent multiple revisions prior to the first shunt infection. Shunt externalization may be ineffective at clearing the infection and should be avoided in favor of early shunt removal and external ventricular drainage, followed by shunt replacement once infection is demonstrated to have cleared.


Assuntos
Derivações do Líquido Cefalorraquidiano/efeitos adversos , Hidrocefalia/cirurgia , Meningomielocele/cirurgia , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Criança , Pré-Escolar , Falha de Equipamento/estatística & dados numéricos , Feminino , Humanos , Hidrocefalia/etiologia , Masculino , Meningomielocele/complicações , Infecções Relacionadas à Prótese/prevenção & controle , Controle de Qualidade , Reoperação , Estudos Retrospectivos
17.
Urology ; 153: 181-184, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33600834

RESUMO

OBJECTIVE: To characterize the rates of endovascular stapler complications during hilar ligation in minimally invasive radical nephrectomy over the last 10 years. MATERIAL AND METHODS: We reviewed the Food and Drug Administration Manufacturer and User Facility Device Experience database from January 1, 2009 to August 1, 2019. Staplers were categorized according to type, namely Ethicon Inc. endocutters (Johnson & Johnson, New Brunswick NJ); Endo-GIA (Medtronic, Minneapolis MN); and Endo-TA (Medtronic, Minneapolis MN). RESULTS: There were 383 cases of complications involving staplers, 63% with Ethicon endocutters; 28% with GIA; and 9% with TA. 22 deaths (5.7% of total complications) were attributed to staplers. No deaths or reoperations occurred due to TA staplers. TA staplers were also associated with a reduced incidence of conversion to open as compared to Ethicon and GIA staplers. Apart from one device, manufacturer evaluation of returned devices either showed no abnormalities or attributed fault to improper use of staplers. DISCUSSION: We characterized stapler complications during a 10-year period for minimally invasive radical nephrectomy. No deaths or reoperations occurred due to TA staplers, perhaps due to cutting and stapling occurring in separate steps. Based on manufacturer evaluation attributing stapling malfunctions to human errors, training of operating room staff on proper use of these devices is critical to prevent potentially significant complications from occurring.


Assuntos
Conversão para Cirurgia Aberta/estatística & dados numéricos , Procedimentos Endovasculares/instrumentação , Falha de Equipamento/estatística & dados numéricos , Nefrectomia , Complicações Pós-Operatórias , Grampeadores Cirúrgicos , Pesquisa Comparativa da Efetividade , Procedimentos Endovasculares/efeitos adversos , Análise de Falha de Equipamento , Humanos , Incidência , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Determinação de Necessidades de Cuidados de Saúde , Nefrectomia/efeitos adversos , Nefrectomia/instrumentação , Nefrectomia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Grampeadores Cirúrgicos/efeitos adversos , Grampeadores Cirúrgicos/classificação , Estados Unidos , United States Food and Drug Administration/normas , United States Food and Drug Administration/estatística & dados numéricos
18.
Neurosciences (Riyadh) ; 26(1): 31-35, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33530041

RESUMO

OBJECTIVES: To determine the prevalence of shunt malfunction without change in ventricle size in imaging modalities, and its clinical presentation. METHODS: A cross-sectional study conducted at King Abdulaziz Medical City, Riyadh, from June 2015 to May 2019. Patient's demographics, clinical presentation and changes in ventricle size were collected. Statistical analysis was done using SPSS version 23. RESULTS: The study included 42 patients who underwent shunt revision. Imaging showed no change in size in 10 (24%) patients, mild enlargement in 8 (19%), and obvious enlargement in 24 (57%). The mean age of diagnosis was 22±16.7. 55% of the patients were males, 45% females. The cause of the malfunction was ventricular catheter occlusion in 14 (34%) patients, 10 (24%) patients had valve-related malfunction, and peritoneal catheter occlusion was present in 6 (14%) patients, and 12 (28%) patients had a combination of the previously mentioned causes. Analysis of the association between ventricular size and headache, vomiting, seizure, confusion, and loss of consciousness in patients with unchanged ventricular size and those with increased ventricular size has shown no statistical significance. CONCLUSION: Shunt malfunction without ventricular size change was observed in 24% of all shunt malfunction patients. In addition, there was no relationship between ventricular size and patient symptoms.


Assuntos
Ventrículos Cerebrais/cirurgia , Falha de Equipamento/estatística & dados numéricos , Hidrocefalia/cirurgia , Derivação Ventriculoperitoneal/efeitos adversos , Adolescente , Ventrículos Cerebrais/diagnóstico por imagem , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Hidrocefalia/diagnóstico por imagem , Lactente , Masculino , Estudos Retrospectivos , Arábia Saudita , Tomografia Computadorizada por Raios X , Adulto Jovem
19.
World Neurosurg ; 148: e627-e634, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33484887

RESUMO

OBJECTIVE: To evaluate incidence and types of implant failure observed in a series of patients with spinal metastases (SM) treated with minimally invasive stabilization surgery without fusion. METHODS: In this multicenter, retrospective, observational study, we reviewed the files of patients >18 years old who underwent surgery for SM using percutaneous spinal stabilization without fusion with a minimum 3-month follow-up. The following variables were included: demographics, clinical findings, prior radiation history, SM location, epidural spinal cord compression scale, Spinal Instability Neoplastic Scale, neurological examination, and surgery-related data. Primary outcome measure was implant failure rate, as observed in patients' last computed tomography scan. Multivariable analysis was performed to identify baseline factors and factors associated with implant failure. RESULTS: Analysis included 72 patients. Mean age of patients was 62 years, 39 patients were men, and 75% of patients had an intermediate Spinal Instability Neoplastic Scale score. Tumor separation surgery was performed in 48.6% of patients. Short instrumentation was indicated in 54.2% of patients. Three patients (4.2%) experienced implant failure (2 screw loosening, 1 screw cut-out); none of them required revision surgery. In 73.6% of cases, survival was >6 months. No significant predictors of failure were identified in the multivariate analysis. CONCLUSIONS: A low implant failure rate was observed over the short and medium term, even when short instrumentations without fusion were performed. These findings suggest that minimally invasive stabilization surgery without fusion may be an effective and safe way to treat complicated SM.


Assuntos
Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Neurocirúrgicos/métodos , Próteses e Implantes , Neoplasias da Coluna Vertebral/secundário , Neoplasias da Coluna Vertebral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Parafusos Ósseos , Falha de Equipamento/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Exame Neurológico , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Compressão da Medula Espinal/diagnóstico por imagem , Compressão da Medula Espinal/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
20.
Am J Obstet Gynecol ; 224(6): 607.e1-607.e17, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33316274

RESUMO

BACKGROUND: No new method of assisting vaginal birth has been introduced into clinical practice since the development of the vacuum extractor in the 1950s. The Odon Device is a new device that employs a circumferential air cuff over the fetal head to assist birth. In this study, the Odon Device has been used to assist vaginal birth for standard clinical indications. OBJECTIVE: This study aimed to investigate the clinical impact, safety, and acceptability of the Odon Device to women, their babies, and clinicians and to assess the feasibility of recruiting women to an interventional intrapartum research study. STUDY DESIGN: This is a nonrandomized, single-arm interventional feasibility study of the Odon Device for operative vaginal birth undertaken in a single maternity unit: Southmead Hospital, Bristol, United Kingdom. The Odon Device was used to assist birth in 40 women who required the birth to be assisted for suspected fetal compromise and/or prolonged second stage of labor. The primary clinical outcome was the proportion of births successfully assisted with the Odon Device, and the primary feasibility outcome was the proportion of eligible women who were approached and who agreed to participate. Neonatal outcome data were reviewed at day 28, and maternal outcomes were investigated up to day 90. RESULTS: Between October 2018 and January 2019, 298 of 384 approached, eligible women (77.6%) consented to participate. Of these women, 40 received the intervention-the use of the Odon Device. Birth was assisted in all cephalic (occiput anterior, occiput transverse, and occiput posterior) fetal positions, at all stations at or below the ischial spine and with or without regional analgesia. The Odon Device was effective in 19 of 40 cases (48%). Of the 40 births, 21 (52.5%) required additional assistance: 18 of 40 births (45%) were completed using nonrotational forceps, 1 of 40 births (3%) required rotational forceps, and 2 of 40 births (5%) required an emergency cesarean delivery. There was no serious maternal or neonatal adverse event related to the use of the device, and there was no serious adverse device effect. There were 4 devices (10%) that were ineffective because of a manufacturing fault. Furthermore, 39 of 40 women (98%) reported a high birth perception score. All practitioners were able to use the device as intended, although some steps in using the device were reported to be easier to perform (setup and deflation of air chamber) than others (application of the device and withdrawal of the applicator). CONCLUSION: Recruitment to an interventional study of a new device for operative vaginal birth was feasible; 78% of eligible women were willing to participate, often expressing an aspiration for an alternative to forceps and vacuum. The success rate of the Odon Device was lower than reported success rates of vacuum and forceps; however, in this study, the device had been used to assist birth for standard clinical indications. There was no significant maternal or neonatal safety concern associated with the use of the device, although the number of births studied was small. Further feasibility study to establish iterative changes to the device, technique, and clinical indications is necessary.


Assuntos
Extração Obstétrica/instrumentação , Complicações do Trabalho de Parto/terapia , Adolescente , Adulto , Falha de Equipamento/estatística & dados numéricos , Extração Obstétrica/métodos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Satisfação do Paciente/estatística & dados numéricos , Gravidez , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...